Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Am J Ophthalmol Case Rep ; 28: 101674, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36545241

RESUMEN

Purpose: To describe a case of paracentral acute middle maculopathy (PAMM) after coronary angiography. Observations: A 65-year-old female patient exhibited a dense central scotoma 5 hrs after coronary angiography. She presented the next day to the retina clinic and received a complete visual examination including slit lamp biomicroscopy, dilated fundus examination, fluorescein angiogram (FA), spectral domain optical coherence tomography (SD-OCT) and OCT-Angiography (OCT-A). She was found to have the characteristic findings of PAMM including a hyperreflective band at the inner nuclear layer (INL) with extension into the inner plexiform layer (IPL) and outer plexiform layer (OPL) on imaging. Conclusions and Importance: PAMM lesions can occur immediately following coronary angiography. The acute nature of the presentation and time to examination in this case lend further insights into the pathophysiology of PAMM. When patients undergo cardiovascular interventions and report new onset visual scotomas, the diagnosis of PAMM should be considered with referral for careful ophthalmic examination and work-up.

3.
Cureus ; 14(10): e30881, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36337789

RESUMEN

Objective In this study, we aimed to investigate whether zinc provided in Age-Related Eye Disease Study 2 (AREDS2) vitamins is associated with a decreased risk of contracting coronavirus disease 2019 (COVID-19). Materials and methods We conducted a retrospective observational cohort study involving patients at a retina-only practice who were provided a questionnaire at each visit to assess whether they were symptomatic of or had contracted COVID-19. Those who answered yes to testing positive for COVID-19 were retrospectively analyzed and categorized based on their AREDS2 vitamin use, and a Pearson's chi-squared test was performed. Demographic data and past ocular history were also analyzed. Results A total of 8,426 unique patients, including 2,111 with a diagnosis of age-related macular degeneration (AMD), were seen from April 1, 2020, to April 9, 2021. A total of 110 patients (1.3%) reported contracting COVID-19 and had positive COVID-19 tests. The average age of those who had contracted COVID-19 in this study was 68.3 years; 51.8% were male, 30.1% had AMD, 28.2% had diabetic retinopathy, 24.5% had surgical retinal disease, 11.8% had retinal vascular disease, and 4.5% had other disease states. Of the COVID-19-positive patients, 27.3% (30/110) took AREDS2 vitamins, while 72.7% (80/110) patients did not. A chi-squared analysis was performed, which was not statistically significant (p=0.667). Conclusions Oral zinc supplementation, in the form of AREDS2 vitamins, is not associated with a protective effect against contracting COVID-19.

4.
Minim Invasive Ther Allied Technol ; 25(6): 319-322, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27384967

RESUMEN

PURPOSE: To evaluate the efficiency and efficacy of two common and commercially available methods to resolve lens fogging: a Fluid Warming System (O.R. Solutions, Chantilly, VA) and the Clearify Visualization System (Covidien, Mansfield, MA). MATERIAL AND METHODS: We prospectively evaluated 40 patients undergoing laparoscopic renal procedures with the Fluid Warming System (first 20 cases) and then the Clearify Visualization System (second 20 cases). We utilized the standard Fluid Warming System per a 30-second modified protocol established in our laboratory. We used the Clearify according to manufacturer instructions. For each procedure we documented the etiology of each episode of visual obstruction, procedure type and surgery duration. We performed a cost analysis. For all cases we used the same insufflator, insufflation trocar location and trocar configuration. RESULTS: All 40 patients completed the study protocol without incident. The mean fogging events per hour for the Fluid Warming System and Clearify Visualization System were 0.7 (0-2.52) and 1.4 (0-5.02), respectively (P = 0.045). Surgery duration and cost per procedure were similar for both systems. CONCLUSION: The Fluid Warming System with modified technique was found to have less fogging events than the Clearify Visualization System, with no difference in operative time or cost.


Asunto(s)
Laparoscopios , Laparoscopía/instrumentación , Laparoscopía/métodos , Diseño de Equipo , Humanos , Riñón/cirugía , Estudios Prospectivos , Instrumentos Quirúrgicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...